40′ x 60′ x 14′ Metal Building Prices

Please CLICK HOME to access our NEW online pricing calculators in Option A, B & C.

You have landed on an out-of-date page.  Thank You.

Hebrews 11:1  Now faith is confidence in what we hope for and assurance about what we do not see.

More

 

Deluxe Steel Building Prices

 

***IMPORTANT INFORMATION ABOUT OPTION A 

  • NO adding or deleting accessories with Option A Packages.
  • Sketches are not to scale:  The roof pitch, as well as the location of roll-up doors, will closely align with the picture shown. 
  • Walk doors and windows are field-located.
  • 130 & 150 mph have wind rated roll up doors, & 40+ lb snow have Northern Ice Gutters and Downspouts.
  • WALK DOORS ARE NOT INCLUDED in 130 and over MPH wind–buying local is recommended.  Framed Opening Kits are given in lieu of Walk Doors.

IF YOU DO NOT FIND YOUR DESIRED BUILDING IN OPTION A, PLEASE GO TO OPTION B.

40 x 60 x 14 deluxe steel building prices

Deluxe    40′ x 60′ x 14 – #1

Key Features Included 

  • Roof Pitch 3:12 with 40-Year Color Roof Warranty
  • 18″ Roof Extensions  w/Soffits
  • Commercial Gutters & Downspouts
  • Two – 12′ x 12′ Insulated Roll Up Doors Located as Shown
  • 3’x7′ Commercial Insulated Walk Door lockset & threshold
  • 1 – 3×3 insulated window
  • Fiberglass 6″ Roof, 4″ Wall WMP VR-R+ Insulation w/tape

40 x 60 x 14 deluxe

Deluxe    40′ x 60′ x 14′ – #2

Key Features Included 

  • Roof Pitch 3:12 with 40-Year Color Roof Warranty
  • 18″ Roof Extensions  w/Soffits
  • Commercial Gutters & Downspouts
  • Two – 12′ x 12′ Insulated Roll Up Door Located as Shown
  • 3’x7′ Commercial Insulated Walk Door lockset & threshold
  • 1 – 3×3 insulated window
  • Fiberglass 6″ Roof, 4″ Wall  WMP VR-R+ Insulation w/tape

40 x 60 x 14 deluxe steel building prices

Deluxe    40′ x 60′ x 14′ – #3

Key Features Included 

  • Roof Pitch 3:12 with 40-Year Color Roof Warranty
  • 18″ Roof Extensions  w/Soffits
  • Commercial Gutters & Downspouts
  • Two – 12′ x 12′ Insulated Roll Up Doors Located as Shown
  • 3’x7′ Commercial Insulated Walk Door lockset & threshold
  • 1 – 3×3 insulated window
  • Fiberglass 6″ Roof, 4″ Wall  WMP VR-R+ Insulation w/tape

40 x 60 x 14 deluxe steel building prices

Deluxe    40′ x 60′ x 14′ – #4

Key Features Included 

  • Roof Pitch 3:12 with 40-Year Color Roof Warranty
  • 18″ Roof Extensions  w/Soffits
  • Commercial Gutters & Downspouts
  • Two – 12′ x 12′ Insulated Roll Up Doors Located as Shown
  • 3’x7′ Commercial Insulated Walk Door lockset & threshold
  • 1 – 3×3 insulated window
  • Fiberglass 6″ Roof, 4″ Wall WMP VR-R+ Insulation w/tape

 

“There is no scarcity of opportunity to make a living at what you love; there’s only scarcity of resolve to make it happen.” -Dr. Wayne Dyer

Standard Features Included In All Models

Our metal buildings come with a 40-year warranty on colored walls and trim, as well as a 25-year galvalume roof warranty. Of course, the building is made of solid I-beam construction, coupled with a lifetime structural warranty. Compared to some firms only using a back-to-back light gauge red iron cee section for the columns and rafters. This lighter material does not hold the same deflections as I-Beam, therefore, those buildings may require additional concrete, in order to support loads which then prevents fasteners from losing integrity over time.
Receive all bolts, screws, closures, weather stripping, sealants, fasteners as required to erect the structure, with a lifetime warranty on roof fasteners. In addition, the pre-punched connecting clips for the structural members, including endwall columns, are welded in place and then primed during fabrication. Of course, all structural elements for the specified framed openings (jamb, girts, and headers) are pre-cut and pre-punched and the necessary clips are welded on during fabrication.

Another great feature is our complete trip package, not to mention our 26 gauge sheeting – 80,000 p.s.i. tensile strength that has a 1 1/4″ sheeting profile.

Equally impressive, is our clear span design (no interior columns), and our purlin bearing rib (PBR) which have a larger overlap than R panels. All panels incorporate the purlin bearing profile. Choose either red or grey interior column finish, however, grey will be an additional cost. Click Specifications for additional information. Foundation plans, anchor bolts, and erection services are not included.

Certification Plans And Manufacturer’s Credentials

While other companies charge extra for stamped plans, IBS includes:

Letter of Certification
2 Sets of erection plans – certified stamped
2 Sets Anchor Bolt plans – certified stamped
Building manufacturer is AISC (American Institute of Steel Construction) accredited and MBMA (Metal Building Manufacturer Association) member.

Metal building prices  posted on website reflect full roof snow load/wind speed | Wind Exposure  – B |  IBC-2015

Please call your local building department to verify codes.


“Always go with your passions.  Never ask yourself if it’s realistic or not.” -Deepak Chopra

join the club

Newsletter

Valuable information. Easily unsubscribe!

Guaranteed Savings:

  • Minimum $500 – $1,000 savings – Average savings is 15% below market rates…

  • plus one ADDITIONAL  feature more than any other offer

Our Terms:

  • 40′ x 60′ x 14′ – 80’x 100′ x 14′ with at least 2 roll up doors, roof & wall insulation included – minimum savings $500.

  • 80’x 100′ x 16′ or larger with at least 2 roll up doors, roof & wall insulation included – minimum savings $1,000.

  • Competitor’s quote must be dated within 2 weeks of the current date.

  • Competitor’s quote must be the same size structure, smae specifications, and accessories included as offered by us.

  • Competitor’s quote must be received by us before customer purchases from us.

  • Competitor’s building must be fabricated from an AISC (Amercian Institute of Steel Construction) certified facility in order to compare equal manufacturing standards.

Low Complexity Defined

We specialize in Low Complexity building design orders.

High complexity building quotes are done on a case by case basis.
What is considered Low complexity:

  • Size: 100 x 500 x 30 max, strictly square or rectangular

  • Roof Pitch: 1:12 through 4:12

  • Endwall & Sidewall Extensions with soffits: 1’ – 5’

  • All Snow & Wind Load Codes Available

  • Partitions and accessories (walk doors, windows, skylights, roll up doors, vents and insulation) available.

If you have questions about whether or not your building is Low or High Complexity, please call  1-800-593-4012

The Basics of Steel Building Codes

In summary, you should be familiar with the following codes prior to building purchase:

  • Snow Load/ Wind Speed
  • Wind Exposure, Example: Exposure B or C
  • Governing Code, Example: IBC 2009, 2014 or 2015
  • Current website prices reflect IBC 2015, Wind Exposure B – Call your local building department to confirm your requirements prior to ordering.

Roof Snow Load Codes/ Wind Speed Code

  • On the website, you will select from the Codes listed in the drop-down menus in Option 1, 2 or 3.
  • Please contact your local building department or Google codes for your zip code.
  • Choose codes from our list that meet or exceed your requirements for accuracy in pricing online:

Roof Snow/ Wind Speed

 0  lb. S/L/130 mph  

 0  lb. S/L/150 mph

 4  lb. S/L/115 mph

 20 lb. S/L115 mph

 30 lb. S/L 115 mph

 40 lb. S/L/115 mph

 60 lb. S/L/115 mph

More About Roof Snow Loads – Pound per Square Foot

Typical snow loads in the United States can range from 4  to 60+ lbs per square foot depending on precipitation. Obviously, in warmer climates there are 0 lb minimum snow load requirements, whereas, in colder states where snow and ice hardly have a chance to thaw before the next storm, roof snow loads can be greater than 60 lbs per square foot.  In addition, snow tends to drift and accumulate heavier in some spots than others, which is why snow loads are a factor in addition to the standard dead loads of a building.

More About Wind Codes – Miles per Hour

Wind load is also determined by patterns of climate local to your building site. Wind speed codes range from 0 mph to over 160 mph winds.

Wind, unlike snow, will affect different portions of the building not limited to only the roof.  The wind’s effects on your steel building structure will vary depending on your building design and how it sits on your property.  During the software designing process, strength factors are determined by building height, the size and number of large framed openings, and even the location of those openings.

Wind Exposure

Also in relation to wind is the exposure of your building. Exposure B or C is site-specific.  For example, in gusty areas, your local building department may require Exposure C if there are no windbreaks provided by your surroundings, such as trees or neighboring buildings. Wind exposure also affects how snow tends to drift and accumulate on your building structure.

Contact Your Local Building Department Early for Governing Codes, such as IBC – 2015

While your metal building broker will ask you to confirm these codes per your local building department, the MBS (design and pricing software used by your broker) will recall default minimums when the representative enters your building site ZIP code.  In many occasions, the local building department will ask you for higher than minimum requirements and dictate which building code year governs these specifics. For example, IBC 2015 or NCBC 2014 (International Building Code for year 2015, or North Carolina Building Code for year 2014, etc.)  

In summary, contact your local building department to get specific governing year code, roof snow requirement, wind speed requirement, and the wind exposure requirement specific to your building site address and ZIP code.  

If you want more education regarding other loads your building is designed for, please click to read “What’s Important About Steel Building Codes”  to learn more.